Diesel Generator Sets
FB10-2
View Product Downloads
- DownloadFB10-2 Brochure
- DownloadRange Brochure
Overview
Our product range designed exclusively for the Indian market is available from 10 – 200 kVA. Designed to meet local legislative requirements for both emissions and noise levels, the range provides outstanding value for money, guaranteeing maximum efficiency and productivity.
Generator Set Specifications
Minimum Rating | 10.0 kVA |
Maximum Rating | 10.0 kVA |
Voltage | 415 Volts |
Frequency | 50 Hz |
Speed | 1500 RPM |
50 Hz Prime Rating | 10.0 kVA |
50 Hz Standby Rating | — |
60 Hz Prime Rating | — |
60 Hz Standby Rating | — |
Generator Set Configurations
Emissions/Fuel Strategy | CPCBII Certified |
Engine Specifications
Engine Model | FBD2-1.2D1 |
Compression Ratio | 19:1 |
Governor Type | Electronic / Isochronous |
Bore | 87.0 mm |
Displacement | — |
Stroke | 100.0 mm |
FG Wilson Diesel Engine
Mecc-Alte Alternator
Mecc Alte is a world leader in the production of synchronous alternators.Worldwide Product Support
FG Wilson manufactures product in the following locations: Northern Ireland • Brazil • China • India • USA With headquarters in Northern Ireland, FG Wilson operates through a Global Dealer Network.Single-Source Supplier
Fully prototype tested with certified torsional vibration analysis availableDesign Critera
Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. Standby Rating These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). Standard Reference Conditions Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.FB10-2Standard Equipment
Air Inlet
- Air Cleaner
Cooling
- Cooling system filled with coolant mix
- Radiator and Cooling Fan
Exhaust
- Exhaust stub pipe & gasket
Fuel
- 75L fuel tank
Alternator
- IP23 Protection
- Mecc-Alte
Mounting
- Anti-vibration mounts
- Base, formed steel with single wall fuel tank
Power
- 3 Pole circuit breaker
General
- Generating set is load tested and all protective devices and control functions are simulated and checked
FB10-2Optional Equipment
Alternator
- Anti-condensation heater
Power Termination
- 4 Pole Circuit Breaker
Starting/Charging
- Lead-Acid Battery (Dry)
General
- CPCBII Compliance
- Neutral Earth Link
- Superior Steel Enclosure